Changes for page Failover - Deploy Possibilities
Last modified by Erik Bakker on 2024/09/27 14:07
From version 28.17
edited by Danniar Firdausy
on 2024/09/25 13:13
on 2024/09/25 13:13
Change comment:
There is no comment for this version
To version 28.22
edited by Danniar Firdausy
on 2024/09/25 13:40
on 2024/09/25 13:40
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,12 +1,9 @@ 1 1 {{container}} 2 2 {{container layoutStyle="columns"}} 3 3 ((( 4 -eMagiz flows, or more specifically, the flows' inbound components, can be grouped. The benefit from this is that you can later in [[Deploy>>doc:Main.eMagiz Academy.Microlearnings.Intermediate Level.Grouping and Failover.intermediate-grouping-and-failover-deploy-possibilities.WebHome||target="blank"]], control them as one entity. This is mainly beneficial when faced with substantial maintenance or outage of systems connected to your eMagiz model. 5 5 6 - Buildingonthisfunctionality,you canevenconfigurethegrouptorunin an active/passivefailover mode whenyou activate themultipleruntimesoption onyourruntime,andeachparateruntimeis deployedon another machine.Thefailover functionality isnotonlyrelevant incasesofservermaintenance.It canalsoassistuwhenyou wanttoexchange data with asystemthat allowsonlyoneactiveconnection.Shouldthis connectionbebusiness-critical,youcan usehisfailover functionalitytocreateapassivefailoversituation thatwill takeover whenthe activeconnection breaksdown (regardlessofthereason).5 +In the previous microlearning, we discussed what situation that failover mode will be beneficial as well as the settings that need to be configured in the Design phase. Next to that, we also discussed that setting up this failover functionality in your model requires you to first execute some steps in your Design, Create, and lastly Deploy phase. Picking up from what we have discussed previously in the Design phase, in this microlearning, we will focus on configuring your setup in the Create phase if you want to activate the active/passive failover configuration. 7 7 8 -Setting up this failover functionality in your model requires you to first execute some steps in your Design, Create, and lastly Deploy phase. In this microlearning, we will focus on configuring your setup in the Create phase if you want to activate the active/passive failover configuration, picking up from what we have discussed previously in the Design phase. 9 - 10 10 Should you have any questions, please get in touch with [[academy@emagiz.com>>mailto:academy@emagiz.com]]. 11 11 12 12 == 1. Prerequisites == ... ... @@ -21,9 +21,9 @@ 21 21 22 22 == 3.1 Settings == 23 23 24 - To configurefailover forsystems that are connectingwithyourmodel, wefirst needto go to the Design phase.InyourDesign>SolutionDesign,find andopenthedetails ofthesystemthatyou wantto enablefailover for.Onceyou dothat,then youeedto makesurethat "Multipleruntimes"option is selected forthissystem, which islogicalsincewe wanttohavea secondruntime running in case offailover situations(e.g.,outage,maintenance,etc.). Afterward, you willsee the "Number ofruntimes" and"Run in failover"fields.Toenablefailover, makesurethat youfill in2 asthe "Numberof runtimes", beforeselecting the"Run infailover"checkbox. See thescreenshotbelowasanexample.21 +After finishing up your configuration in the Design phase, you can then go to the Settings page on the top right corner of the Create phase. In this page, under the "Failover systems" tab in the "Transfer settings from design" section, you will find the system connector(s) that you can transfer the failover settings from Design. 25 25 26 -[[image:Main.Images.Microlearning.WebHome@grouping-and-failover--intermediate-grouping-and-failover-setting-up-failover- design-phase-solution-design.png]]23 +[[image:Main.Images.Microlearning.WebHome@grouping-and-failover--intermediate-grouping-and-failover-setting-up-failover-create-phase-create-settings.png]] 27 27 28 28 {{info}}Systems with the failover option enabled must have "Number of runtimes" exactly 2 and must be placed on an external machine in the Architecture panel.{{/info}} 29 29