Changes for page Cleanup Alerting in Manage
Last modified by Danniar Firdausy on 2024/09/18 13:49
From version 11.1
edited by Erik Bakker
on 2022/08/30 09:51
on 2022/08/30 09:51
Change comment:
There is no comment for this version
To version 6.1
edited by Erik Bakker
on 2022/08/30 09:30
on 2022/08/30 09:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,33 +14,30 @@ 14 14 15 15 === 3.1 Scenario's when to cleanup the Alerting phase === 16 16 17 -* A user is no longer active on the integration model. 18 - ** The user may still be referenced in the notification settings and should be removed 19 -* A specific runtime is removed from the integration model that is referenced in the Alerting 20 -* A flow or integration is removed from the integration model that is reference in the Alerting 17 +1. A user is no longer active on the integration model. The use may still be referenced in the notification settings and should be removed 18 +2. A specific runtime is removed from the integration model that is referenced in the Alerting 19 +3. A flow or integration is removed from the integration model that is reference in the Alerting 21 21 22 22 === 3.1 Steps to clean === 23 23 24 - Once you have opened your model you should navigate to theManage environment. From here you should open the Alerting section under Manage and selectTriggers.Here you can change the relevant triggers.23 +Navigate to the Triggers first. 25 25 26 -**Queue specific** 25 +1. Locate Queue specific 26 + If you have configured the alerting following the best practice outlined in the user guide for Alerting, the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 27 27 28 -If you have configured the alerting following the best practice outlined in the user guide for Alerting, the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 29 - 30 30 * Standard – Queue consumers too high 31 31 * Standard – Queue consumers too low 32 32 33 -**Runtime specific** 31 +2. Locate Runtime specific 32 + If you are removing the last flow belonging to a system and you have followed the best practice outlined here the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 34 34 35 -If you are removing the last flow belonging to a system and you have followed the best practice outlined here the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 36 - 37 37 * Standard – Data measurements missing 38 38 * Standard – Log entries missing 39 39 * Standard – Error log entry 40 40 41 - *Once you have located the candidates, update and/or remove the triggers relevant for update42 - *Review if you need to remove a notification setting in case a trigger is removed. If yes, remove it.43 - *Review if you need to remove a tag in case the tag is not used in any trigger. If yes, remove it.38 +3. Once you have located the candidates, update and/or remove the triggers relevant for update 39 +4. Review if you need to remove a notification setting in case a trigger is removed. If yes, remove it. 40 +5. Review if you need to remove a tag in case the tag is not used in any trigger. If yes, remove it. 44 44 45 45 == 4. Assignment == 46 46