Changes for page Cleanup Alerting in Manage
Last modified by Danniar Firdausy on 2024/09/18 13:49
From version 13.5
edited by Danniar Firdausy
on 2024/09/05 12:22
on 2024/09/05 12:22
Change comment:
There is no comment for this version
To version 8.1
edited by Erik Bakker
on 2022/08/30 09:49
on 2022/08/30 09:49
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. dfirdausy1 +XWiki.ebakker - Content
-
... ... @@ -8,52 +8,53 @@ 8 8 9 9 == 2. Key concepts == 10 10 11 -This microlearning is about cleaning up the Alerting as configured in the Manage phase. Alerts can be set on various ways and levels. During the cleanup of various systems, flows and runtime, the Alerting needs to remain current with the integration model. 11 +This microlearning is about cleaning up the Alerting as configured in the Manage phase. Alerts can be set on various ways and levels * please inspect the related microlearnings around alerting to understand more about that. During the cleanup of various systems, flows and runtime, the Alerting needs to remain current with the integration model. 12 12 13 -{{info}}Please inspect the related microlearnings around [[alerting in eMagiz>>doc:Main.eMagiz Academy.Microlearnings.Crash Course.Crash Course Platform.crashcourse-platform-manage-alerting-gen3||target="blank"]] to understand more about that topic.{{/info}} 14 - 15 15 == 3. Cleanup the Alerting in Manage == 16 16 17 17 === 3.1 Scenario's when to cleanup the Alerting phase === 18 18 19 -* A user is no longer active on the integration model. 20 - ** The user may still be referenced in the notification settings and should be removed 17 +* A user is no longer active on the integration model. The use may still be referenced in the notification settings and should be removed 21 21 * A specific runtime is removed from the integration model that is referenced in the Alerting 22 22 * A flow or integration is removed from the integration model that is reference in the Alerting 23 23 24 24 === 3.1 Steps to clean === 25 25 26 - Once you have opened your model you should navigate to theManage environment. From here you should open the Alerting section under Manage and selectTriggers.Here you can change the relevant triggers.23 +Navigate to the Triggers first. 27 27 28 -**Queue specific** 25 +* Locate Queue specific 26 + If you have configured the alerting following the best practice outlined in the user guide for Alerting, the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 29 29 30 -If you have configured the alerting following the best practice outlined in the user guide for Alerting, the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 28 + ** Standard – Queue consumers too high 29 + ** Standard – Queue consumers too low 31 31 32 -* Standard – Queueconsumerstoo high33 - *Standard–Queueconsumers toolow31 +* Locate Runtime specific 32 + If you are removing the last flow belonging to a system and you have followed the best practice outlined here the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 34 34 35 -**Runtime specific** 34 + ** Standard – Data measurements missing 35 + ** Standard – Log entries missing 36 + ** Standard – Error log entry 36 36 37 -If you are removing the last flow belonging to a system and you have followed the best practice outlined here the following triggers (at least!!!) need to be changed. For your specific situation more triggers could be relevant 38 - 39 -* Standard – Data measurements missing 40 -* Standard – Log entries missing 41 -* Standard – Error log entry 42 - 43 43 * Once you have located the candidates, update and/or remove the triggers relevant for update 44 44 * Review if you need to remove a notification setting in case a trigger is removed. If yes, remove it. 45 45 * Review if you need to remove a tag in case the tag is not used in any trigger. If yes, remove it. 46 46 47 -== 4. Keytakeaways==42 +== 4. Assignment == 48 48 44 +Determine whether you can clean up parts of the Alerts from the project that you work on. If so, execute the cleanup. 45 +This assignment can be completed with the help of the (Academy) project that you have created/used in the previous assignment. 46 + 47 +== 5. Key takeaways == 48 + 49 49 * Cleaning up the Alert phase is important to ensure no false positive alerts are created/used 50 50 * Review the Alert setting at each release to production (post deployment step) to keep things manageable 51 51 52 -== 5. Suggested Additional Readings ==52 +== 6. Suggested Additional Readings == 53 53 54 -* [[Crash Courses (Menu)>>doc:Main.eMagiz Academy.Microlearnings.Crash Course.WebHome||target="blank"]] 55 -** [[Crash Course Platform (Navigation)>>doc:Main.eMagiz Academy.Microlearnings.Crash Course.Crash Course Platform.WebHome||target="blank"]] 56 -*** [[Standard Alerting eMagiz (Explanation)>>doc:Main.eMagiz Academy.Microlearnings.Crash Course.Crash Course Platform.crashcourse-platform-manage-alerting-gen3||target="blank"]] 54 +None 57 57 56 +== 7. Silent demonstration video == 58 58 58 +None 59 + 59 59 )))((({{toc/}}))){{/container}}{{/container}}