Changes for page Runtime Overview Exit codes
Last modified by Carlijn Kokkeler on 2024/09/17 15:13
From version 3.1
edited by Eva Torken
on 2024/03/22 15:42
on 2024/03/22 15:42
Change comment:
There is no comment for this version
To version 9.1
edited by Tudor Neacsu
on 2024/06/21 09:00
on 2024/06/21 09:00
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - No Data DeliveredtoBackendSystem1 +Runtime Overview Exit codes - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. etorken1 +XWiki.TudorNeacsu - Content
-
... ... @@ -1,32 +1,33 @@ 1 1 {{container}}{{container layoutStyle="columns"}}((( 2 -In this document, we willusetheinformationfrom theactualroot causeanalysisto makea genericviewthatcanbeusedifyouruninto thesameorasimilarproblem in thefuture.Finally,the documentwilldescribethe situation,the problem,theanalysis, andtheresult.2 +In this microlearning, we will give insights into what is an exit code, the main exit codes returned by a container when it stops and how can that help a Support Engineer to conduct an RCA. 3 3 4 4 Should you have any questions, please get in touch with [[academy@emagiz.com>>mailto:academy@emagiz.com]]. 5 5 6 -== 1. Situation ==6 +== 1. Key concepts == 7 7 8 -No data is delivered to a backend system. 9 9 10 -== 2. Problem==9 +== 2. Exit code values == 11 11 12 - Theprobleminthiscasewasthat thebackendsystemwas notreceivinganydata.This wascaused byanunstableH2 database.11 +* Exited with code **0**: The application inside the container completed its work successfully without any errors. 13 13 14 - ==3.Analysis==13 +* Exited with code **1**: There was a general error in the application, which could be due to a variety of reasons like incorrect arguments or a failed dependency. 15 15 16 - ===3.1Reproduction===15 +* Exited with code **125**: The docker run command was not executed successfully 17 17 18 - N/A17 +* Exited with code **126**: The command inside the container was found but cannot be executed. This can be due to permission issues or if the command is not executable. 19 19 20 - ===3.2Analysis===19 +* Exited with code **127**: The command was not found. This usually happens if a script is missing or the path is not set correctly. 21 21 22 - Theproblemledus toinvestigatethe healthof theH2database. The databasehad a very high CPU andhad high CPU afterthe connector underwentauto-healing. Afterfurther investigationiteemedthat the H2 wasreprocessingmessages andthereforenot taking on new ones.21 +* Exited with code **137**: The container was forcefully stopped. This happens when the container exceeds its memory resource limit (OOM) 23 23 24 -== 4. Result == 23 +* Exited with code **139**: The application inside the container crashed due to a segmentation fault, which is usually caused by accessing memory that the process does not have permission to access. 24 + 25 +* Exited with code **255**: Container exited, returning an exit code outside the acceptable range, meaning the cause of the error is not known 25 25 26 -The removal and re-addition of the H2 database caused the H2 database to return to normal behavior. Afterwards, the problem did not reoccur. 27 27 28 28 == 5. Suggested Additional Readings == 29 -N/A 29 +For more information on resetting a H2 Database, please check out the following microlearning: 30 +* [[Reset H2 Database>>doc:Main.eMagiz Academy.Microlearnings.Intermediate Level.eMagiz Runtime Management.intermediate-runtime-management-reset-h2.WebHome||target="blank"]] 30 30 31 31 32 32 )))((({{toc/}}))){{/container}}{{/container}}